CX1-B0-16-660-3DA-10C [Carling Technologies]
MAGNETIC CIRCUIT BREAKER,;型号: | CX1-B0-16-660-3DA-10C |
厂家: | Carling Technologies |
描述: | MAGNETIC CIRCUIT BREAKER, 电路保护 |
文件: | 总13页 (文件大小:2096K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CX
eries-Series
CX-S
CIRCUIT BREAKER
The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the
breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a
patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating
the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent
magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase
the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An
enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat
transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced
splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction
Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance
even in the most demanding applications.
Resources:
Configure a Complete Part
Download CAD & Sales Drawing
Watch Product Video
Product Highlights:
•ꢀ ULꢀ489ꢀ&ꢀULꢀ489BꢀListed
•ꢀ TUVꢀCertifiedꢀIEC/ENꢀ60947-2
•ꢀ Temperatureꢀstableꢀhydraulic-magneticꢀꢀ
ꢀ overcurrentꢀsensingꢀtechnology
•ꢀ Optionalꢀrelayꢀtripꢀcircuitꢀpermittingꢀremoteꢀꢀ
ꢀ operatorꢀsystemꢀshutꢀdown
•ꢀ Perfectꢀfitꢀforꢀ380VDCꢀApplications
High DC Voltage Applications:
•ꢀ Datacom,ꢀPDUꢀandꢀUPSꢀSystems
•ꢀ PowerꢀSuppliesꢀandꢀConvertors
•ꢀ MissionꢀCriticalꢀEquipment
•ꢀ RenewableꢀEnergyꢀSystems
•ꢀ MotorꢀControllers
ꢀ
ꢀ
•ꢀ ChargingꢀStations
•ꢀ SmartꢀGrids
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
2
CX-Series Circuit Breaker – Design Features
CX-Series
DESIGN FEATURES
HYDRAULIC/MAGNETIC
SENSING COIL
UPPER ARC RUNNER
Aids in motivating arc off of movable
contact and into arc chamber
MAGNETS
ARC SPLITTER
RETAINER
with integrated
pressurizing walls
PATENT PENDING MAGNETIC FLUX
BOOSTING TERMINAL CONFIGURATION
Design enhances motivation
(12) ARC DEIONIZING
SPLITTER PLATES
LOWER ARC RUNNER
LARGE ARC GAP
To generate high
arc voltages
Aids in motivating arc
off of stationary contact
and into arc chamber
of arc into arc chamber
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
3
CX-Series Circuit Breaker – General Specifications
Electrical Tables
Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker
CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS
VOLTAGE
CIRCUIT
MAX CURRENT INTERRUPTING
NUMBER
CONFIGURATION
RATING AMPS CAPACITY (AMPS) OF POLES
MAX. RATING FREQUENCY
1
2
2
250
D.C.
D.C.
D.C.
15
15
50
5,000
10,000
10,000
250 / 500
410 / 205
SERIES
Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector
CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR
VOLTAGE
MAX
CURRENT
RATING AMPS
INTERRUPTING
CAPACITY
(AMPS)
CIRCUIT
CONFIGURATION
NUMBER APPLICATION
OF POLES
CODE
MAX.
RATING
FREQUENCY
300
300
440
440
600
600
D.C.
D.C.
D.C.
D.C.
D.C.
D.C.
1 - 75
76 - 125
1 -30
5,000
3,000
10,000
5,000
5,000
3,000
1
1
2
2
2
2
TC1, OL0, U3
TC1, OL0, U3
TC1, OL0, U3
TC1, OL0, U3
TC1, OL0, U3
TC1, OL0, U3
SERIES
31 - 63
1 - 75
76 - 115
SWITCH ONLY1
600
D.C.
1 - 115
----
2 or 3
---
Notes:
1
Requires inclusion of a relay trip voltage coil
Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch
CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH
VOLTAGE
CIRCUIT
CURRENT RATING INTERRUPTING
CONSTRUCTION
NOTES
CONFIGURATION MAX RATING FREQUENCY POLES
(AMPS)
RATING (AMPS)
May have a third pole
that is a voltage
trip pole
600
600
DC
DC
21
42
50 - 100
600
SERIES
May have a fifth pole
that is a voltage
trip pole
110 - 175
600
Notes:
1
2
Two poles in series.
Two poles in series in parallel with 2 poles in series.
Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switch gear and Control gear - Circuit Breakers
CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR &
CONTROL GEAR / CIRCUIT BREAKER
INTERRUPTING
CAPACITY
VOLTAGE
CIRCUIT
CURRENT RATING
(AMPS)
CONFIGURATION
MAX.
ICS / ICU
(AMPS)
FREQUENCY
DC
POLES
2
RATING
SERIES
440
1-63
4,000
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
CX-Series Circuit Breaker – General Specifications
Electrical
Mechanical
Maximum Voltage
Overload
600 VDC
Endurance
Max 10,000 ON-OFF operations @
6 per minute; 6000 with rated
current & voltage, and 4,000 cycles
mechanical.
50 operations at 600% of rated
current for UL489, and at 150% of
rated current for UL1077.
Trip Free
Trips on overload even when
actuator is forcibly held in the “On”
position.
The operating handle moves
positively to the “Off” position when
an overload causes the breaker
to trip.
RESISTANCEPERPOLEVALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
1000
100
10
CURRENT
(AMPS)
TOLERANCE
(%)
Trip Indication
0.10 - 5.0
5.1 - 20.0
20.1 - 50.0
15
25
35
O
H
M
S
1
Environmental
Shock
Withstands 100 Gs, 6ms saw tooth
while carrying rated current per
MILPRF-55629 and MIL-STD-
202G, Method 213G, Test Condition
“I”. Instantaneous and ultra short
curves tested at 90% of rated current
Withstands 0.060” excursion
from 10-55 Hz & 10 Gs 55-500 Hz,
at rated current per MIL-PRF-55629
and MILSTD-202G, Method 204D,
Test Cond. A. Instantaneous &
ultrashort curves tested at 90% of
rated current.
MIL-PRF-55629 and MIL-STD-
202G, Method 106G, i.e., Ten 24-
hour cycles at +25°C to +65°C, 80-
98% RH.
Method 101, Condition A (90-95%
RH at 5% NaCl Solution, 96 hrs).
MIL-PRF-55629 and MIL-STD-
202G, Method 107G, Condition A
(5-cycles at -55°C to +25°C to
+85°C to +25°C).
0.1
0.01
0.001
0.01
0.1
1
10
100-110205
AMPERE RATING
Vibration
Physical
Number of Poles
Termination
1- 2 poles, + Auxiliary Switch Pole.
10-32 or M5 Screw Terminals
1/4-20 or M6 Threaded Stud
Terminals
Termination Barrier
Mounting
Standard with multi-pole constructions
Threaded insert: #6-32 UNC-2B, or
M3X0.5-6H B ISO (2 per pole)
Handle, 1 per pole.
Moisture Resistance
Actuator
Internal Circuit Config.
Materials
Series Trip
Salt Spray
Housing - Glass filled Polyester
Handle - Glass filled Polyester
Line/Load Terminals - Copper Alloy.
~150 Grams (~5.3 Ounces).
~150 Grams (~5.3 Ounces).
Housing - Gray.
Thermal Shock
Weight
Standard Color
Operating Temperature
-40°C to +85°C.
Handle - White, Black, Red, Green,
Blue, Yellow, Gray,
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
5
CX-Series Circuit Breaker - UL489 – Ordering Scheme
C X 1 B 0 14 615 2 2 A 12 G
8
9
10
Mounting
Inserts
11
Rating
12
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color &
Legend
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
1 SERIES
C
8 TERMINAL
2
3
5
6
Screw Terminal, 10-32
Stud, 1/4-20
Screw Terminal, M5
Stud, M6
2 ACTUATOR
Handle, one per pole
X
9 ACTUATOR COLOR & LEGEND
3 POLES
Actuator Color
White
Black
I-O
A
C
F
ON-OFF
Dual
Legend Color
Black
White
White
White
White
Black
Black
Black
1
2
One
Two
B
D
G
J
1
2
3
4
5
6
7
8
Red
Green
Blue
Yellow
Gray
H
K
M
P
4 CIRCUIT
Series Trip current
L
(
)
B
N
Q
S
5 AUXILIARY/ALARM SWITCH
Without Aux Switch
Orange
R
0
10 MOUNTING INSERTS
6 FREQUENCY & DELAY
A
B
6-32 Thread
M3 Thread
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
11 MAX. APPLICATION RATING
12 250 VDC
13 250/500 VDC
1
7 CURRENT RATING (AMPERES)
CODE AMPERES
15 205/410 VDC
220 0.20
225 0.25
230 0.30
235 0.35
240 0.40
245 0.45
250 0.50
255 0.55
260 0.60
265 0.65
270 0.70
275 0.75
280 0.80
285 0.85
290 0.90
295 0.95
410 1.00
512 1.25
415 1.50
517 1.75
420 2.00
522 2.25
425 2.50
527 2.75
430 3.00
435 3.50
440 4.00
445 4.50
450 5.00
455 5.50
460 6.00
614 14.00
615 15.00
616 16.00
617 17.00
618 18.00
620 20.00
622 22.00
624 24.00
625 25.00
630 30.00
635 35.00
640 40.00
645 45.00
650 50.00
465 6.50
470 7.00
475 7.50
480 8.00
485 8.50
490 9.00
495 9.50
610 10.00
710 10.50
611 11.00
711 11.50
612 12.00
712 12.50
613 13.00
12 AGENCY APPROVAL
A
G
S
Without Approvals
UL 489 Listed
UL 489 Listed, TUV to IEC60947-2
1
Notes:
1
Only Available with 250/500 VDC up to 15 amps.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
CX-Series Circuit Breaker - UL489B – Ordering Scheme
C X 2 S 0 03 810 3 2 A 06 14
8
9
10
Mounting
Inserts
11
Rating
12
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color &
Legend
Series
Actuator
Poles
Circuit
Relay Trip
Frequency
& Delay
Current Rating
4,5
1 SERIES
8 TERMINAL
C
3
6
Stud, 1/4-20
Stud, M6
A
B
Stud, 1/4-20, with 10-32 Screw Terminals on Voltage Pole
Stud, M6, with M5 Screw Terminals on Voltage Pole
2 ACTUATOR
X
Handle, one per pole
9 HANDLE COLOR & LEGEND
1,2
3 POLES
Actuator Color
White
Black
I-O
A
C
F
ON-OFF
Dual
Legend Color
Black
White
White
White
White
Black
Black
Black
2
3
4
5
Two
B
D
G
J
1
2
3
4
5
6
7
8
Three
Four
Five
Red
Green
Blue
Yellow
Gray
H
K
M
P
L
N
Q
S
4 CIRCUIT
Switch Only
S
Orange
R
1,2
5 RELAY TRIP VOLTAGE COIL RATING
10 MOUNTING INSERTS
6-32 Thread
0
Without Relay Trip Voltage Coil
A
B
M3 Thread
A
B
C
D
12 VDC
24 VDC
32 VDC
48 VDC
11 MAX. APPLICATION RATING
06 600VDC
6 FREQUENCY & DELAY
03 DC Switch Only
12 AGENCY APPROVAL
A
Without Approvals
UL489B Listed
14
1,3
7 CURRENT RATING (AMPERES)
Notes:
1
2 Pole Unit is required for ratings between 50A - 100A.
4 Pole Unit is required for ratings between 110A - 175A.
2-Pole Section
2
A Relay Trip Voltage Coil Pole may be added to either the 2 or 4 Pole construction.
The addition of this extra pole dictates a change in the designation for the number of
poles in selection 3.
For Current Ratings between 50A - 100A select current code 810 (100A).
For Current Ratings between 101A - 175A select current code 917 (175A).
Voltage Pole must have screw terminals.
Switch Pole must have stud terminals.
On 3 Pole Unit, Voltage Pole to be located at P1 as standard.
On 5 Pole Unit, Voltage Pole to be located at P3 as standard.
810
50A - 100A
4-Pole Section
917 110A - 175A
3
4
5
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
7
CX-Series Circuit Breaker - UL1077 – Ordering Scheme
C X 1 B 0 14 620 2 2 A 10 C
8
9
10
Mounting
Inserts
11
Rating
12
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color &
Legend
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
8
1 SERIES
8 TERMINAL
C
2
3
5
6
Screw, 10-32
Stud, 1/4-20
Screw, M5
Stud, M6
2 ACTUATOR
X
Handle, one per pole
9 ACTUATOR COLOR & LEGEND
7
3 POLES
Actuator Color
White
Black
I-O
A
C
F
ON-OFF
Dual
Legend Color
Black
White
White
White
White
Black
Black
Black
1
2
3
4
One
Two
Three
Four
B
D
G
J
1
2
3
4
5
6
7
8
Red
10
Green
Blue
Yellow
Gray
H
K
M
P
L
N
Q
S
4 CIRCUIT
1, 9
)
(
Switch Only no coil
Series Trip current
Relay Trip voltage
A
B
G
Orange
R
(
(
)
1, 2, 3, 9
)
10 MOUNTING INSERTS
A
B
6-32 Thread
M3 Thread
5 AUXILIARY SWITCH
Without Aux Switch
0
11 MAX. APPLICATION RATING
6 FREQUENCY & DELAY
10
11
14
06
18
300VDC
03
10
11
12
14
16
DC 50/60Hz, Switch Only
4
440 VDC without factory installed terminal bus
440VDC with factory installed terminal bus
600VDC
220/440VDC
DC Instantaneous
DC Ultra Short
DC Short
DC Medium
DC Long
4
5
11
12 AGENCY APPROVAL
A
C
Without Approvals
UL 1077 Recognized
6
7 CURRENT RATING (AMPERES)
CODE AMPERES
9
Wꢀ
ULꢀ1077ꢀRecognizedꢀ&ꢀTUVꢀCertifiedꢀIEC/ꢀENꢀ60947-2
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
665 65.000
670 70.000
675 75.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.000
911 115.000
912 125.000
Notes:
1
Only available when tied to a protected pole.
Requires special part number consult factory for details
Voltage trip circuit coil not rated for continuous duty - use instantaneous delay code 10
Contacts Rated for 20A @ 80 VDC
440ꢀVDCꢀRatingꢀavailableꢀinꢀtwoꢀdifferentꢀwiringꢀconfigurations.ꢀ
600 VDC only available with factory installed terminal bus.
Single pole units available up to 125A, multi pole units limited to 115A Max.
3 Pole units must include one Auxiliary switch pole (circuit code A or G) - Requires Special
Part Number. Unless breaker is rated 220/440 VDC (Voltage Code 18) in which case
Circuit Code B is required.
2
3
4
5
6
7
8
9
Screw Terminals are limited to 50A max.
Agency approval code W only available with 440 VDC or 220/440 VDC rating and
circuit code B.
10 4 Pole 600 VDC units only available up to 75A Max.
11 3ꢀPoleꢀ220/440ꢀVDCꢀunitsꢀonlyꢀavailableꢀinꢀoneꢀspecificꢀwiringꢀconfiguration.
Seeꢀdimensionalꢀspecificationsꢀpagesꢀforꢀmoreꢀdetails
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
CX-Series Circuit Breaker - UL489 Listed – Dimensional Specifications
Dimensional Specifications: in. [mm]
2.259+0.020
[57.38+0.50]
0.265
[6.73]
0.502
[12.75]
0.755
0.579
[14.72]
[19.18]
MAXIMUM
1.719
[43.66]
0.380
[9.65]
1.843+0.020
[46.81+0.50]
+0.050
–0.020
+1.27
–0.50
3.094
78.59
2.062+0.020
[52.37+0.50]
30.0º
1.052
[26.72]
0.124
[3.16]
0.626+0.020
[15.90+0.50]
2.264+0.020
[57.51+0.50]
SHOWN WITH STUD
TERMINAL CONFIGURATION
1.017
[25.82]
1.515
[38.48]
MAXIMUM
3.672
[93.268]
2.259
[57.38]
&
(205/410 VDC)
2.736
SHOWN WITH SCREW
TERMINAL CONFIGURATION
[69.49]
0.744
[18.90]
(WITH SCREW TERMINAL)
2.946
1.520
[38.61]
[74.83]
(WITH STUD TERMINAL)
0.760
[19.30]
0.156 TYP
[3.96]
3.276
[83.21]
(UNFOLDED BARRIER)
REW TERMINAL)
2.946
1.520
[38.61]
[74.83]
UD TERMINAL)
3.276
[83.21]
0.760
[19.30]
0.156 TYP
[3.96]
FOLDED BARRIER)
1.062
[26.97]
TOLERANCES +.005[.12]
2.062
[52.37]
0.750 TYP
[19.05]
0.625
[15.88]
CX1
CX2
Notes:
1
2
All dimensions are in inches [millimeters].
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.
CLA-8119 Rev: C
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
9
CX-Series Circuit Breaker - UL489B – Dimensional Specifications
Dimensional Specifications: in. [mm]
OPTIONAL VOLTAGE POLE
SEE NOTE 1
POLE 1
CX3
POLE 2
POLE 3
CX2
CX3 - 2 POLE SWITCH (CX2)SHOWN
WITH OPTIONAL VOLTAGE POLE
50A-100A DEVICE, 600VDC
POLE 1
OPTIONAL VOLTAGE POLE
SEE NOTE 2
POLE 2
POLE 3
SEE NOTE 3
POLE 4
POLE 5
CX5 - 4 POLE SWITCH (CX4)SHOWN
WITH OPTIONAL VOLTAGE POLE
101A-175A DEVICE, 600VDC
Notes:
1
2
3
4
All dimensions are in inches [millimeters].
3ꢀpoleꢀconfigurationꢀsuppliedꢀwithꢀvoltageꢀcoilꢀonꢀpoleꢀ1.ꢀOptionalꢀlocationꢀpoleꢀ3.ꢀConsultꢀfactory.
5ꢀpoleꢀꢀconfigurationꢀsuppliedꢀwithꢀvoltageꢀcoilꢀinꢀcenterꢀpole.ꢀ(Poleꢀ3)
Line & Load connections requires bus connection as shown.
2
2
Minimum cross selection .127 in (81.94 mm )
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
CX-Series Circuit Breaker - UL1077 – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
600V Rating requires minimum of 2 protected poles
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
11
CX-Series Circuit Breaker - UL1077 – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
600V Rating requires minimum of 2 protected poles
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
Sales Representatives, Distributors & Company Profile
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_06_2019
相关型号:
CX1-C-SM1-10.0M100/50/C
Parallel - Fundamental Quartz Crystal, 10MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-155.52M100/100/M
Quartz Crystal, QUARTZ CRYSTAL RESONATOR, 155.52 MHz, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-155.52M100/20/I
Quartz Crystal, QUARTZ CRYSTAL RESONATOR, 155.52 MHz, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-155.52M100/30/M
Parallel - Fundamental Quartz Crystal, 155.52MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-155.52M100/50/C
Parallel - Fundamental Quartz Crystal, 155.52MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-250.0M100/10/C
Parallel - Fundamental Quartz Crystal, 250MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-250.0M100/100/I
Quartz Crystal, QUARTZ CRYSTAL RESONATOR, 250 MHz, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-250.0M100/20/I
Parallel - Fundamental Quartz Crystal, 250MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-250.0M100/30/M
Quartz Crystal, QUARTZ CRYSTAL RESONATOR, 250 MHz, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-250.0M100/50/C
Parallel - Fundamental Quartz Crystal, 250MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
CX1-C-SM1-32.0M100/10/C
Parallel - Fundamental Quartz Crystal, 32MHz Nom, LEAD FREE, HERMATIC SEALED, LEADLESS, MINIATURE, CERAMIC, SMD, 2 PIN
EUROQUARTZ
©2020 ICPDF网 联系我们和版权申明